Catalytic 3GAUQA 125

Material Safety Data Sheet

Product And Company Identification

Catalytic 3g Aqua 125 (Oxygen Scavenger, Liquid) Revision date: 25/03/2008
Supplier Catalytic 3GAQUA CHEMICALS PVT.LTD
Address Plot no. 338- scheme no. 94, f-201, Gulmohar enclave ring road near, Mayor hospital INDORE M.P.INDIA.452016.
For non-emergency information: Telephone number:91-9300443555
For emergency Telephone number:
Spill Emergency91-9669945500
Health Emergency 91-9300904222
Chemtrec 91-9300443555

 

Composition/Information On Ingredients

Combination of chemicals and salts thereof having deficiency of oxygen and comparatively less stable like sulphites, hydro sulphites, hydrazine, and catalysts and stabilizers.

 

Hazards Identification

Emergency Overview Appearance
  • FormClear liquid
  • ColorPale yellow to yellow
  • OdorAlmost odorless

 

Hazard Summary

  • Emergency overview: water treatment chemical
  • Non-corrosive compound
  • May be harmful if swallowed
  • Non Toxic

 

Potential Health Effects Primary Routes of Entry

Eye contact Direct contact with material can cause the following: Irritation
Skin contact Prolonged or repeated skin contact can cause the following: Irritation
Inhalation Non-hazardous

 

Environmental effects

On the basis of available information, this material is not expected to produce any significant adverse environmental effects when recommended use instructions are followed.

 

First Aid Measures

General Grossly contaminated clothing: Wash before re-use.
Inhalation Move to fresh air.
Skin contact Wash with water and soap as a precaution.If skin irritation persists, call a physician.
Eye contact Rinse with plenty of water.If eye irritation persists, consult a specialist.
Ingestion Drink 1 or 2 glasses of water.Consult a physician immediately.Never give anything by mouth to an unconscious person.Do not induce vomiting.

 

Fire-Fighting Measures

Flash point Non combustible
Lower explosion limit Not applicable
Upper explosion limit Not applicable
Thermal decomposition >230.00
Suitable extinguishing media Water spray, foam, dry chemical, or carbon dioxide. Use extinguishing media appropriate for surrounding fire.
Specific hazards during fire fighting When heated to decomposition, it may emit toxic fumes of so2
Special protective equipment for fire-fighters Wear self-contained breathing apparatus and protective suit.

 

Accidental Release Measures

Personal precautions Use personal protective equipment and clothing.
Environmental precautions Non-corrosive, non-combustible, non-hazardous material
Methods for cleaning up Wash out spills with plenty of water. Transfer liquids and solid spilled material to separate suitable containers for recovery or disposal.

 

Handling and Storage

Handling Handle with care. Wash thoroughly after handling. Avoid contact with clothing.
Storage water treatment chemical
Store in a tightly closed container. Store in a cool, dry, well-ventilated area, away from incompatible substances like explosives.

 

Exposure Controls / Personal Protection

Exposure limit(s) Exposure limits are listed below, if they exist.
Eye protection: safety glasses with side-shields. Eye protection worn must be compatible with respiratory protection system employed.
Hand protection: The glove(s) listed below may provide protection against permeation. Gloves of other chemically resistant materials may not provide adequate protection):Neoprene gloves
Respiratory Protection: A respiratory protection program meeting OSHA 1910.134 and ANSI Z88.2 requirements or equivalent must be followed whenever workplace conditions warrant a respirator's use.None required under normal operating conditions.Where vapors and/or mists may occur, wear a properly fitted NIOSH approved (or equivalent) half-mask, air-purifying respirator.Air-purifying respirators should be equipped withNIOSH approved (or equivalent) organic vapor cartridges and N95 filters. If oil mist is present, use R95 or P95 filters.
Protective measures: Facilities storing or utilizing this material should be equippedwith an eyewash facility.
Engineering measures: Use adequate general or local exhaust ventilation to keep airborne concentrations below the permissible exposure limits.

 

Physical and Chemical Properties

Appearance
  • FormLiquid
  • ColorWater white to pale yellow
  • OdorAlmost odourless
  • pH7.0-8.0
  • Boiling point/range100°C (212°F) Water
  • Melting point/range0°C (32°F) Water
  • Flash pointNoncombustible
  • Lower explosion limitNot applicable
  • Upper explosion limitNot applicable
  • Vapor pressure5.0 mmHgat20°C (68.00 °F) Water
  • Relative vapor density < 1.0 water
  • Water solubilitycompletely soluble
  • Relative density 1.10
  • Viscosity, dynamic100.000 - 500.000 cps 25°c
  • Evaporation rate < 1.00 Water
NOTE:

The physical data presented above are typical values and should not beconstrued as a specification.

 

Stability and Reactivity

Hazardous reactions None known. Stable , However, avoid temperatures above 230C/446F, the onset of polymer decomposition Thermal decomposition is dependent on time and temperature
Materials to avoid There are no known materials which are incompatible with this product
Hazardous decomposition products Not hazardous, Hazardous polymerization will notoccur

 

Toxicological Information

IARC carcinogenic category none
Epidemiology No data available
Acute oral toxicity Not established
Acute dermal toxicity Not established
Skin irritationrabbit No skin irritation
Eye irritationrabbit slight irritation

 

Ecological Information

Do not allow the compound to reach ground water sources.

 

Disposal Considerations

Environmental precautions CAUTION: Keep spills and cleaning runoff out of municipalsewers and open bodies of water.
Disposal Waste Classification Dilute with water. Dispose of in a manner consistent withlocal regulations.

 

Transport Information

  • US DOT – domestic Not-regulated
  • IMO - international
  • DOT Domestic, Not regulated
  • IMO/IMDGNot regulated (Not dangerous for transport)

 

Regulatory Information

Workplace Classification
This product is considered non-hazardous under the , OSHA Hazard Communication Standard ,(29CFR1910.1200). This product is not a 'controlled product' under the Canadian Workplace Hazardous Materials Information System (WHMIS).
SARA Title III: Section 311/312 Categorizations (40CFR370)
This product is not a hazardous chemical under 29CFR 1910.1200, and therefore is not covered by Title III of SARA.
SARA Title III: Section 313 Information (40CFR372)
This product does not contain a chemical which is listed in Section 313 at or above deminimis concentrations.
CERCLA Information (40CFR302.4)
Releases of this material to air, land, or water are not reportable to the NationalResponseCenter under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) or to state and local emergency planning committees under the Superfund Amendments and Reauthorization Act (SARA) Title III Section 304.
US Toxic Substances Control Act (TSCA)
All components of this product are in compliance with the inventory listing requirements of the U.S. Toxic Substances Control Act (TSCA) Chemical Substance Inventory.
Pennsylvania
Any material listed as "Not Hazardous" in the CAS REG NO. column of SECTION 2, Composition/Information On Ingredients, of this MSDS is a trade secret under the provisions of the Pennsylvania Worker and Community Right-to-Know Act.

 

Other Information

Hazard Rating

HealthFireReactivity HMIS100000

Legend

  • ACGIH American Conference of Governmental Industrial Hygienists
  • BAcButyl acetate
  • OSHA Occupational Safety and Health Administration
  • PELP ermissible Exposure Limit
  • STEL Short Term Exposure Limit
  • TLV Threshold Limit Value
  • TWA Time Weighted Average (TWA):
  • Bar denotes a revision from prior MSDS

 

Notice

This material safety data sheet must be made available to all persons who, by the nature of their employment, may handle or come into contact with this material.

 

Disclaimer

The percentage weight (% w/w) of ingredients is not to be taken as a specification guaranteed by Catalytic 3gaqua chemicals pvt. Ltd., but only as an approximate guide to the content of hazardous ingredients in the material. The information contained herein does not constitute a guarantee by Manhar Specialities concerning the properties of the material.

The information contained in this material safety data sheet is offered in good faith and is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as guidance for safe handling, use, processing, storage, transportation, disposal and release and is offered without warranty, representation, inducement or licence and Catalytic 3gaqua chemicals pvt. Ltd assumes no legal responsibility for reliance upon same. Catalytic 3gaqua chemicals pvt. Ltd disclaims any liability for loss, injury or damage incurred in connection with the use of the material or its associated material safety data sheet.

This information is not be construed as a representation that the material is suitable for any particular purpose or use except those conditions and warranties implied by either commonwealth or state statutes. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text. Customers are encouraged to make their own enquiries as to the material's characteristics and, where appropriate, to conduct their own tests in the specific context of the material's intended use.